Status numbers

<< 点击显示目录 >>

主页  ACOPOS 6D使用手册 > mapp 6D  > 功能块 > McAcp6D  >

Status numbers

 

Topics in this section:

-1065811967: 6DNet disconnected

-1065811966: Segment version does not match.

-1065811965: Segment bootup failed. System was unable to detected the configured Segments, as in, the configured Segments was not detected in the physical layout

-1065811964: More shuttles are loaded than configured

-1065811963: No shuttles found

-1065811962: Invalid shuttle position

-1065811961: Shuttle ID scan failed

-1065811960: Segment enable failed

-1065811959: 6D controller bootup failed

-1065811958: Segment configuration failed

-1065811957: One or more shuttles cannot be identified

-1065811956: One ore more shuttles are rotated out of limits

-1065811955: One or more shuttles cannot be enabled

-1065811954: Pre-assigned shuttle ID error

-1065811869: Undefined assembly error, internal error code: {ErrorCode}

1081671782: Command initialization of assembly started

1081671783: Assembly created

-1065811864: Failed to create assembly

-1065811863: The command {=$BR/GMC/Enum/Acp6DFbName/{CommandName} is not available for ACOPOS6D.

-1065811862: Name is missing in configuration file

-1065811861: File device was not configured, the directory is missing or the file is read-only.

-1065811860: Error while writing the file '{FileName}'.

-1065811859: Cannot write to the file '{FileName}'. File is read-only.

-1065811858: {FunctionBlock} cannot be used in the current state ({AssemblyState}).

-1065811857: Power on failed.

-1065811856: Power off failed.

-1065811855: Insufficient memory to create the amount of shuttles according to the configured pool size.

-1065811854: Insufficient memory to create the amount of shuttles according to the configured pool size.

1081671795: Writing config {Step} of {TotalNumStep}

1081671881: Shuttle {ShuttleName} created.

-1065811766: Failed to create shuttle {ShuttleName}.

1081671883: Shuttle {ShuttleName} registred.

1081671884: Shuttle {ShuttleName} removed.

-1065811763: Failed to remove shuttle {ShuttleName}.

1081671886: Shuttle {ShuttleName} deregistred.

1081671887: Shuttle {ShuttleName} deleted

-1065811747: Shuttle Stereotype {ShuttleName} already exists.

-1065811746: Failed to create shuttle stereotype {ShuttleStereotype}. Max (254) shuttle stereotypes are already defined for shuttle type ({ShuttleType}).

-1065811745: Failed to create shuttle stereotype {ShuttleName}.

-1065811744: Shuttle stereotype {1} is not defined.

-1065811743: Failed to create shuttle stereotype {ShuttleStereotype}. Default shuttle stereotype for shuttle type ({ShuttleType}) is already defined.

-1065811737: No free cyclic channels (max = 9)

1081671912: Cyclic channel: {CyclicChannel} found

1081671913: Cyclic channel : {CyclicChannel} released.

1081671914: Cyclic channel : {CyclicChannel} ready.

-1065811717: Failed to create Macro {MacroName}. Max (64) macros are already defined.

-1065811716: Macro {MacroName} already exists.

-1065811715: Failed to create macro {MacroName}.

-1065811714: Macro {MacroName} is not existing.

-1065811713: Maximum number of macro shuttles is already active ({UINT}). Save existing macro shuttles to remove them.

-1065811712: No macros defined.

-1065811667: No layout specified. Check your configuration!

-1065811666: No input array specified. Check your configuration!

-1065811665: No output array specified. Check your configuration!

-1065811664: Invalid Segment configuration.

1081671985: Segment {SegmentName} registred.

1081671986: Segment {SegmentName} created.

-1065811661: Failed to create segment {SegmentName}.

1081671988: Assembly state changed from {AssemblyState} to {AssemblyState}.

-1065811568: Value of {UINT} in the settings is invalid. Value was {FLOAT}. Valid range is from {FLOAT} to {FLOAT}.

-1065811567: Value of {UINT} in the settings is invalid. Value was {UINT}. Valid range is from {UINT} to {UINT}.

-1065811566: Value of {STRING} in the settings is invalid. Value was {STRING}. Valid range is from {STRING} to {STRING}.

1081672181: Zone {ZoneName} created.

-1065811466: Failed to create zone {ZoneName}.

1081672183: Zone {ZoneName} registred.

1081672281: Shuttle group {ShGroupName} created.

-1065811366: Failed to create shutte group {ShGroupName}.

1081672283: Shuttle group {ShGroupName} registred.

-1065811364: No free shuttle groups available.

1081672285: {UINT} shuttles added to the shuttle group.

1081672286: Shuttle group {ShGroupName} deleted

-1065809912: Value of Maximum Shuttles in the settings is invalid. Value is {NumberOfShuttles}.

-1065807872: Power Sector is in error state.

-1065803776: Invalid assembly state

-1065803775: No mastership

-1065803774: Waiting for mastership timeout

-1065803773: Wrong group state

-1065803772: Wrong macro state

-1065803771: Wrong digital IO state

-1065803770: Wrong segment state

-1065803768: No routing solution for asynchronous movement

-1065803767: Internal communication timeout

-1065803766: Invalid license

-1065803765: Wrong stereotype state

-1065803764: Command event already assigned

-1065803763: Command event buffer is full

-1065803762: Fieldbus communication error

-1065803761: User configuration backup failed

-1065803760: User configuration reading failed

-1065803759: File open failure

-1065803758: Save gcode failure

-1065803757: Invalid gcode

-1065801969: General CMD Error - TBD

-1065801966: The ACOPOS6D object is invalid.

-1065801965: The ACOPOS6D object was changed since last call to the function block.

-1065801964: Error in Acopos 6D Configuration.

-1065801963: 6D controller: Lost Powerlink communication

1081681686: 6D controller: Established Powerlink communication

-1065799680: Wrong shuttle state

-1065799679: Invalid shuttle position

-1065799678: Shuttle weighing timeout

-1065795584: Invalid parameters

-1065795583: Invalid config file

-2139533792: The handle PV '{ProcessVariable}' does not exist

-2139533791: Failed to connect handle PV '{ProcessVariable}' (Status={Status})

-2139533790: The handle PV '{ProcessVariable}' is of an invalid type (expected {DataType})

1081691683: Successfully connected PV '{ProcessVariable}'.

-1065791488: Wrong queue state

-1065791487: Wrong zone state

-1065791486: A shuttle is located on the zone boundary

-1065791485: Invalid auto loading zone state

-1065791484: Invalid traffic road state

-1065790968: The maximum number of shuttles as configured for the shuttle pool has been exceeded.

-1065790967: No more shuttles available on the assembly.

-1065790966: No more segments available on the assembly

-1065790965: No more zones available on the assembly.

-1065781967: Shuttle state error. Shuttle: {ShuttleID}, Axis: {Axis}

-1065781966: Shuttle feedback position error. Assembly cannot track the shuttle anymore. Shuttle: {ShuttleID}, Axis: {Axis}

-1065781965: Lag error during motion. Shuttle: {ShuttleID}, Axis: {Axis}

-1065781964: Lag error during standstill. Shuttle: {ShuttleID}, Axis: {Axis}

-1065781963: Fatal shuttle error. Shuttle: {ShuttleID}, Axis: {Axis}

-1065781962: Invalid parameter detected in motion buffer. Shuttle: {ShuttleID}, Axis: {Axis}

-1065781869: Undefined shuttle error, internal error code: {ErrorCode}

-1065780967: Power on segment failed. Segment: {SegmentID}

-1065780966: Internal 12V power supply error. Segment: {SegmentID}

-1065780965: 6D Link Error between 6D controller and master segment. Segment: {SegmentID}

-1065780964: Overcurrent motor coil. Segment: {SegmentID}

-1065780963: Overcurrent internal 12V Power supply. Segment: {SegmentID}

-1065780962: Overcurrent internal 24V Power supply. Segment: {SegmentID}

-1065780961: CPU voltage 3 error. Segment: {SegmentID}

-1065780960: CPU voltage 2 error. Segment: {SegmentID}

-1065780959: CPU voltage 1 error. Segment: {SegmentID}

-1065780958: Under voltage internal 24V Power supply. Segment: {SegmentID}

-1065780957: Over voltage internal 24V Power supply. Segment: {SegmentID}

-1065780956: Under voltage internal 12V Power supply. Segment: {SegmentID}

-1065780955: Over voltage internal 12V Power supply. Segment: {SegmentID}

-1065780954: CPU temperature error. Segment: {SegmentID}

-1065780953: Amplifier temperature error. Segment: {SegmentID}

-1065780952: Motor temperature error. Segment: {SegmentID}

-1065780951: Analog V1 under voltage error. Segment: {SegmentID}

-1065780950: Analog V1 over voltage error. Segment: {SegmentID}

-1065780949: Analog V2 under voltage error. Segment: {SegmentID}

-1065780948: Analog V2 over voltage error. Segment: {SegmentID}

-1065780947: Analog V3 under voltage error. Segment: {SegmentID}

-1065780946: Analog V3 over voltage error. Segment: {SegmentID}

-1065780945: Analog V4 under voltage error. Segment: {SegmentID}

-1065780944: Analog V4 over voltage error. Segment: {SegmentID}

-1065780943: Analog V5 under voltage error. Segment: {SegmentID}

-1065780942: Analog V5 over voltage error. Segment: {SegmentID}

-1065780869: Undefined segment error, internal error code: {SegmentID}

-1065777969: Undefined error type: internal error code: {ErrorCode}

1081721680: 6D Controller changed state from {ControllerState} to {ControllerState}

1081733120: {FunctionBlockName} call

1081733121: {FunctionBlockName} acknowledge

1081733122: {FunctionBlockName} done

1081733123: {FunctionBlockName} aborted

-1065750524: The function block was called without a valid interface

-1065746433: Command not supported