MC_BR_PowerSecDeactivate_Acp6D

<< 点击显示目录 >>

MC_BR_PowerSecDeactivate_Acp6D

This function block deactivates all segments within the power sector.

Requirements for use

Assembly states in which this function block is permitted to be used:

AssemblyReady

Function block

mc_br_powersecdeactivate_acp6d

Interface

I/O

Parameter

Data type

Description

IN

PowerSec

Reference to Mc6DPowerSecType

The power sector reference establishes the connection between the function block and a power sector.

IN

Execute

BOOL

Execution of the function block begins on a rising edge of this input.

OUT

Done

BOOL

Execution successful, function block finished.

OUT

Acknowledge

BOOL

The command is accepted and saved by the ACOPOS 6D controller.

OUT

Busy

BOOL

The function block is active and must continue to be called.

OUT

CommandAborted

BOOL

The command was aborted by another command.

OUT

Error

BOOL

Error during execution.

OUT

ErrorID

DINT

Error number

Table: Parameter

Topics in this section:

Function description