MC_BR_PowerSecGetShuttle_Acp6D

<< 点击显示目录 >>

主页  ACOPOS 6D使用手册 > mapp 6D  > 功能块 > McAcp6D  > Function blocks  >

MC_BR_PowerSecGetShuttle_Acp6D

This function block returns the references for all shuttles within the range of the power sector.

Function block

mc_br_powersecgetshuttle_acp6d

Interface

I/O

Parameter

Data type

Description

IN

PowerSec

Reference to Mc6DPowerSecType

The power sector reference establishes the connection between the function block and a power sector.

IN

Enable

BOOL

The function block is active as long as this input is set.

OUT

Next

BOOL

Execution of the function block is started on a rising edge of the input.

OUT

Valid

BOOL

The function block output values can be used.

OUT

Busy

BOOL

The function block is active and must continue to be called.

OUT

Error

BOOL

Error during execution.

OUT

ErrorID

DINT

Error number

OUT

TotalCount

UINT

Total number of shuttles

OUT

RemainingCount

UINT

Number of shuttles still to pass through

OUT

Shuttle

Mc6DShuttleType

Shuttle reference

OUT

TotalCount

McAcp6DGetShAddInfoType

Additional information about the shuttle

Table: Parameter

Topics in this section:

Function description